RW11、RW12 OUTDOOR HIGH-VOLTAGE DROP FUSE

Short Description:

RW, HRW, HPRW series outdoor high-voltage drop-out fuses (hereinafter referred to as “fuse”) are used in the power system of AC 50Hz, voltage 12kV, 35kV, application for short-circuit and overload protection of power lines and power equipment, and open and close current.


Product Detail

Product Tags

Product Overview

   RW, HRW, HPRW series outdoor high-voltage drop-out fuses (hereinafter referred to as "fuse") are used in the power system of AC 50Hz, voltage 12kV, 35kV, application for short-circuit and overload protection of power lines and power equipment, and open and close current.
Working Environment
1. Ambient air temperature: upper limit +40℃ , lower limit -30℃ ;
2. Altitude: ≤ 1000m;
3. Relative humidity: daily average value is not more than 95%, monthly average value is not more than 90%;
4. No frequent severe vibration;
5. Pollution level: Grade III;
6. There is no place with fire, explosion hazard and chemical corrosion.
Product Mix
The fuse is mainly composed of an insulating support and a fuse tube. The static contacts are installed at both ends of the insulation support, and the dynamic contacts are installed at both ends of the fuse tube. The fuse tube consists of an inner arc suppression tube and an outer phenolic tube. Composed of paper or epoxy glass cloth tube.
Drop fuse

图片12

Model NO. Rated voltage(A) Rated current(A) Breaking current (A) Impulse voltage (BIL) Power frequency withstand voltage Creep distance (MM) Weight (KG) Dimension (CM)
RW11-12KV

12

100 6300 110 42

260

7.5 48×32×27
RW11-12KV

12

200 8000 110 42

260

7.5
Model NO. Rated voltage (A) Rated current(A) Breaking current (A) Impulse voltage (BIL) Power frequency withstand voltage Creep distance (MM) Weight (KG) Dimension (CM)
RW12-12KV

12

100 6300 110 40

250

6.5 40×36×11.5
RW12-12KV

12

200 10000 110 40

250

6.5
Model NO. Rated voltage(A) Rated current(A) Breaking current (A) Impulse voltage (BIL) Power frequency withstand voltage Creep distance (MM) Weight (KG)  Dimension (CM)
RW12-15KV

15

100 8000 125 45

320

7.5 50×36×12.5
RW12-15KV

15

200 12500 125 45

320

7.5
Model NO. Rated voltage(A) Rated current(A) Breaking current (A) Impulse voltage (BIL) Power frequency withstand voltage Creep distance (MM) Weight (KG) Dimension (CM)
RW12-12、15KV(ABB) 12、15 100 8000 125 45

320

7.5 50×36×12.5
RW12-12、15KV(ABB) 12、15 200 12500 125 45

320

7.5

 

COMPOSITE ZINC OXIDE SURGE ARRESTOR