GW4-40.5 OUTDOOR HIGH VOLTAGE DISCONNECTING SWITCH

Short Description:

GW4-40.5 outdoor disconnecting switch is an AC 50Hz outdoor high- voltage electrical equipment. It is used to open and close high-voltage lines under no-load conditions, as well as to electrically isolate the high- voltage lines of the overhauled high-voltage bus, circuit breaker and other electrical equipment. It can be used to open and close small capacitor or inductor current.This series of outdoor disconnecting switches meets the relevant regulations of GB1985 “AC High Voltage Disconnecting Switches and Earthing Switches”, IEC60129 “AC Disconnecting Switches and Earthing Switches” and GB/T11022 “Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards” and other standards


Product Detail

Product Tags

Product Overview
   GW4-40.5 outdoor disconnecting switch is an AC 50Hz outdoor high- voltage electrical equipment. It is used to open and close high-voltage lines under no-load conditions, as well as to electrically isolate the high- voltage lines of the overhauled high-voltage bus, circuit breaker and other electrical equipment. It can be used to open and close small capacitor or inductor current.

   This series of outdoor disconnecting switches meets the relevant regulations of GB1985 “AC High Voltage Disconnecting Switches and Earthing Switches”, IEC60129 “AC Disconnecting Switches and Earthing Switches” and GB/T11022 “Common Technical Requirements for High Voltage Switchgear and Control Equipment Standards” and other standards
Main Technical Parameters

No. Item Unit Data
1 Rated voltage kV 40.5
 2 Rated insulation level 1 min Power frequencywithstand voltage (valid value)

To earth

kV 95

 Fracture

kV 115

Lightning impulse withstand voltage (peak)

 To earth

kV 185

 Fracture

kV 215
3 Rated frequency Hz 50
4 Rated current A

400

630

1000

1250

1600

2000 3150

4000

5 4s short-time withstand current kA

16

20

31.5

31.5

40 40 50

50

6 Peak withstand current kA

40

50

63 80

100

100 125

125

7 Rated short time withstand current duration main blade/grounding blade s 4/2
 8 Rated terminal mechanical load Horizontal longitudinal load N 750
Horizontal lateral load N 500
Vertical force N 750
9 Creepage distance mm 1025~1250
10 Mechanical life Times 2000
11 Manual operating mechanism No grounding   CS11(F)
single grounding   CS8-6D(F)
double grounding   main blade CS14G(F ) ; grounding blade CS11(F)
 12 Motor operating mechanism Model NO.   CJ5/CJ6
Motor voltage V AC380,AC220,DC220V
Controlling circuit voltage V AC220,DC220
Opening and closing time S 6±1
13 Product weight No grounding kg 360
single grounding kg 410
double grounding kg 460