GN38-12 indoor high-voltage disconnecting switch type indoor high-voltage disconnecting switch is designed and manufactured to meet the needs of fixed high-voltage cabinets and ring mains cabinets to compact and miniaturize. It has a three-station structure, a fully insulated bottom plate, and is equipped with a coaxial lock and a complete mechanical interlocking mechanism, which is compact and small. It is the best option switch for compact box switch cabinet Reference standard:GB1985-1989 AC high voltage disconnecting switch and grounding switch IEC129-84 AC disconnecting switch and grounding switch


Product Detail

Product Tags

Product Overview
   GN38-12 indoor high-voltage disconnecting switch type indoor high-voltage disconnecting switch is designed and manufactured to meet the needs of fixed high-voltage cabinets and ring mains cabinets to compact and miniaturize. It has a three-station structure, a fully insulated bottom plate, and is equipped with a coaxial lock and a complete mechanical interlocking mechanism, which is compact and small. It is the best option switch for compact box switch cabinet Reference standard:GB1985-1989 AC high voltage disconnecting switch and grounding switch IEC129-84 AC disconnecting switch and grounding switch
Working Environment
1. The altitude is below 2000m;
2. Ambient air temperature: upper limit +40℃ , lower limit -25℃ ;
3. Relative humidity: daily average value is not more than 95%, monthly average value is not more than 90%;
4. The surrounding air should not be significantly polluted by corrosive orflammable gas, water vapor, etc.;
5. No frequent severe vibration.
Main Technical Parameters

 No.  Item Unit  Data
1 Rated voltage kV 12
2 Rated frequency HZ 50
3 Rated current A 630-1250
4 Rated thermal stability current (4s) kA 25-31.5
5 Rated dynamic stability current kA 63-80
 6 Rated insulation level 1 min Power frequency withstand voltage  kV Over the ground and interphase 42;The isolation of fracture 48
Lightning impulse withstand voltage Over the ground and interphase 75;The isolation of fracture 85

Appearance And Installation Dimensions

053FA5A6-EE33-4b4e-8F82-2988B68B8C18

1. Dynamic contact blade   8. Manual operation positioning mechanism
2. Static contact   9. Base
3. Incoming terminal   10. Busbar through-wall insulation bottom plate
4. Insulation support   11. Outlet terminal
5. Insulation rod   12. Grounding contact
6. Operation panel   13. Grounding busbar
7. Interlocking mechanism   14. Grounding screw

 

 